NF44

Typical frequency response for Standard Series NF44 Servo valve shown below

NF44

Typical frequency response for Standard Series NF44 Servo valve shown below

  • Specify rated control flow in GPM within limits of table - Lower rated flows available on special order

    Specify supply pressure from 500 to 4000psi to nearest 50psi - Lower and higher pressures available on special order

Supply Pressure (no load valve pressure drop) PSI Rangeof No-Load Rated flow with MIL-PFR-83282
MinimumValue MaximumValue
CIS GPM CIS GPM
500 34 8.8 69 18
1000 46 12 100 26
1500 56 14 120 31
2000 61 16 139 36
2500 68 18 155 40
3000 73 19 170 44
3500 77 20 183 48
4000 84 22 196 51
  • Cable location over C1 or C2 only choice for Series NF44

Nominal Supply Pressure(psi)
500 1000 2000 3000
Maximum amplitude ratio < 2dB < 2dB < 2dB < 2dB
Frequency of 90˚ Phase Point > 40Hz > 55Hz > 65Hz > 80Hz

Stock Series NF44(Part number NF44-I10)

Supply pressure 3000psi
Rated flow 170cis(44gpm) no-load
66cis(17gpm) at 1000psi valve drop
O-rings NBR
Test fluid MIL-PRF-83282
Rated current 10mA
Coil resistance - 1000 ohms/coil
Coil connection Individual coil
Connector Bendix PC-02E-8-4P
Cable location Over pressure port C2
상단으로